IMAGE ORTHICON CAMERA TUBE PDF

Image Orthicon is a photoemissive type of camera tube. Photoemission is the basis of its working. This camera tube was invented in the year by Radio Corporation of America. Photocathode acts as a primary element in the operation of image orthicon.

Author:Dougal Nibar
Country:Madagascar
Language:English (Spanish)
Genre:Politics
Published (Last):4 December 2016
Pages:34
PDF File Size:20.92 Mb
ePub File Size:17.77 Mb
ISBN:324-2-80194-599-3
Downloads:60139
Price:Free* [*Free Regsitration Required]
Uploader:Vudojar



Image Orthicon is a photoemissive type of camera tube. Photoemission is the basis of its working. This camera tube was invented in the year by Radio Corporation of America. Photocathode acts as a primary element in the operation of image orthicon. This is so because photocathode allows the emission of electrons from its surface when light from a scene is allowed to incident on it. We know the basic operation of camera tubes includes the change of optical energy into electrical energy. And to achieve this, an image orthicon makes use of photoemissive material i.

As it is clear from the above figure that the whole structure is divided into 3 sections which are as follows:. The image section consists of photocathode formed by coating the inner surface of a glass faceplate with silver-antimony-cesium. A lens system is used that focuses the image from a scene on the surface of the photocathode. This incident light from the image allows the emission of electrons from the surface of the photocathode.

The surface of the photocathode is semi-transparent in nature. Thereby allowing penetration of incidenting light into the inner surface from where the electron emission is taking place. Photocathode emits the charge stored in it by the action of light energy. Therefore, the structure is designed in a way that electrons emitted from the surface of the photocathode are accelerated towards the target plate. In the structure of image orthicon, the focusing coil allows focused striking of the electron beam at the target.

The structure holds the electron gun and multiplier stage that provides the desired video signal. The working of image orthicon is explained in detail under the three sections, so consider the above figure and proceed:. When light from a scene falls on the surface of photocathode then electrons are emitted from its surface. Due to the semi-transparent nature of the cathode surface, the light penetrates in order to reach the inner surface of the material.

The number of emitted electrons will be directly proportional to the intensity of the optical image falling on the surface. The emission of electrons from the surface of the cathode leads to the formation of an electron image on the target side of the photocathode.

As we have already discussed under construction that potential at the target plate is comparatively higher than the potential at the photocathode.

Thus the resultant electric field provides proper acceleration, thereby allowing the movement of electrons towards the target plate. But the electrons in motion possess the tendency of repelling each other while moving, and this resultantly distorts the information present in the form of charge image. So to avoid this, an axial magnetic field is provided by the use of a focusing coil.

The magnetic field focusses the emitted electrons on the surface of the target plate in the form of definite electron image of the actually provided optical image. The high-velocity electrons emitted from the surface of the photocathode when bombards the surface of the target then secondary electrons are emitted from the surface of the target. The wire-mesh screen present in front of the target plate collects these secondary electrons.

Due to the emission of secondary electrons, a positive charge distribution is created on the surface of the target plate. This distribution of positive charge on the target surface is proportional to the intensity of incidenting optical image on the surface of the photocathode. As we have already discussed that target is made of the thin glass sheet, this is basically done to prevent the spreading of stored charge over the surface of the target. As spreading of charge will hinder the resolution of the device.

As the presence of cesium at the target surface provides high secondary emission ratio. Therefore, this leads to higher intensity of positive charge distribution at the target than charge produced emitted by the photocathode. This increase in charge density at the target wrt charge at the photocathode is called image multiplication.

This resultantly enhances the overall sensitivity of the image orthicon. Due to the thin structure of the target plate, the stored positive stored charge appears on the other side of the target which is subjected to scanning. And the video signal is achieved from this particular side of the target plate. To facilitate the neutralization of stored charge, a scanning electron beam is used.

Let us now understand the further process. The electron gun emits an electron beam for scanning the charges at the target plate. Basically, the beam emitted by the cathode of the gun is focussed towards the target by the help of the magnetic field produced by an external focus coil and the potential at grid 4.

The potential at the target is nearly 0 V thus electrons in motion stop their movement at the target surface. To prevent the emission of secondary electrons at the surface of the target, certain deceleration is provided to the beam approaching the target by grid 5. So, the electrons in the beam reaches the target with almost zero velocity and neutralizes the positive charge present on the plate.

But only the number of electrons required to neutralize the positive charge is deposited on the plate while the rest returns towards the first electrode of the multiplier. But as continuous generation of positive charge is taking place at target due to continuous incidenting of the optical energy. Therefore, after each scanning beam, the target will again hold the positive charge. As a constant amount of electrons are emitted by the beam for each scanning.

Thus after each scanning different amount of electrons will be deposited on the target surface and rest will move towards the gun. And the deposition will depend on the positive generated charge according to the intensity of incident light or the picture information at the photocathode.

It is to be noted here that a low-velocity beam when approaches the target, tries to glide along its surface in tangential manner and this causes loss of resolution. Thus, it is required that the scanning beam must strike the target at the right angle to achieve good resolution.

And so to achieve this combined action of electrostatic and magnetic field must be utilized. Hence the interaction of two fields causes cycloidal motion of the beam that leads to striking the target at right angle irrespective of the scanning point. The beam returning from the target plate reaches a disc which covers the gun electrode present close to the aperture from where the beam emerged.

The potential at the disc is nearly V wrt the target and this disc acts as the initial stage of the multiplier. The figure below shows the complete multiplier stage which is composed of 5 different stages having different potential:. The return beam when strikes the disc then secondary emission of electrons takes place. So, these secondary electrons get attracted towards the dynodes present at successively greater potentials, as shown in the figure shown above.

And therefore called signal multiplication , thereby providing high SNR. The variation in the anode current is proportional to the variation existing in the return beam from the target and amplification by the multiplier.

Thus we can say that voltage across load resistor R L is the required video signal. And its amplitude is dependent on the brightness variation of the optical image. Image orthicon camera tubes were initially used in studios for live shows and for remote pickups that require the accommodation of a wide range of lighting conditions. Your email address will not be published.

Skip to content. Leave a Comment Cancel Reply Your email address will not be published.

BUDDHISM AS PHILOSOPHY SIDERITS PDF

The Image Orthicon

It is a sensitive tube and handling a wide range of light values and contrast. This tube makes use of the high photoemissive sensitivity obtainable from photocathodes, image multiplication at the target caused by secondary emission and an electron multiplier. It has three main sections:. A photosensitive surface, called photocathode , acting as main transducer in image orthicon camera tube.

DSD FLIPCHART PDF

Video camera tube

Photoelectronic Imaging Devices pp Cite as. The image orthicon IO was developed during World War II to solve some of the problems of its predecessors in the camera-tube family. These included poor sensitivity, spurious signals, and unstable operation. The solution was good enough that it made commercial television practicable, and in fact good enough that the IO was the best camera tube available for over twenty years.